elektro-automatik电源EA-PS8080归零;德国elektro-automatik电源EA-PS 8080-40 2U/EA-PSI 8160-60 2U Offset Tool Instructions
1. Preparation
a. Connect PS/PSI via USB interface, wait for driver to install. Make sure, only one PS/PSI 8000 is connected to the PC.
b. Make shortcut on DC output. Cable cross section must be sufficient for the max. current of your device!
c. Switch on device
d. Start PS8000_offset_tool.exe
2. Tool
a. Click button 1. Wait for the device to be found and correctly displayed in the 6 fields.
b. Click button 2.
c. Click button 3. A field “Offset in Ampere” will appear:
i. The device will set 0 A. If there is a positive current offset it will be shown, like in the screenshot above.
ii. Field “I monitor” will show a value, most likely negative.
iii. Adjust that value downwards, i. e. increase it by steps of 1 or 10 with the small arrows or enter it directly with the keyboard. Continue increasing “I monitor” until “Offset in Ampere” reaches 0. Best is to have the offset be a little over 0, for example 0,001…0,003 (models with 2 decimal places for current on display) resp. 0,01…0,03 (models with 1 decimal place for current on display)
d. Click button 4.
e. Click button 5.
i. The device will set max. current now! Another field “Offset in Ampere” will appear (beneath button 6), showing the offset (negative or positive) at max. current.
ii. Repeat the same procedure as in step 2-c-iii. with the “I select” field next to button 6. Rules:
1. If offset is negative, make value in “I select” positive.
2. If offset is positive, make value in “I select” negative.
iii. Adjust the value in “I select” until “Offset in Ampere” shows almost zero. It is recommended to keep a small positive offset.
f. Click button 6.
g. Click button 7.


elektro-automatik电源EA-PS8080归零;德国elektro-automatik电源EA-PS 8080-40 2U/EA-PSI 8160-60 2U偏置补偿工具指令
1。准备
A.将PS / PSI通过USB接口,等待驱动程序安装。确保只有一个PS / PSI 8000连接到PC。
B.在直流输出上做快捷方式。电缆横截面必须足以满足您设备的zui大电流.!
C 开启电源
D.安装ps8000_offset_tool.exe
2。工具
点击按钮1。等待在6个字段中找到并正确显示的设备。
点击按钮2。
点击按钮3。一个字段“抵消安培”将出现:
一,设备将设置0答:如果有一个积极的电流偏移将显示,如在上面的截图。
II。现场“我显示器”将显示价值,zui有可能的负面。
三、向下调整该值,即用小箭头加1或10步,或用键盘直接输入。继续增加“我监测”,直到“抵消安培”达到0。是有偏移是0多一点,例如0001…0003(小数点后2位为当前显示模式)或。0.01 0.03(与…当前显示1位小数的模型)
D.点击按钮4。
点击按钮5。
设备将设置zui大电流现在!另一个字段“抵消安培”将出现(下面按钮6),显示偏移量(负或正)在zui大电流。
II。重复同样的程序,如步骤2-c-iii.与“我选择”字段旁边的按钮6。规则:
1。如果偏移量为负值,则在“我选择”正。
2。如果偏移为正,使“i选择”负值为负值。
调整“我选择”的值,直到“抵消安培”显示几乎为零。建议保持一个小的正偏移。
点击按钮6。
点击按钮7。